(888) 764-3080

Home › The Published Dimensions

The Published Dimensions

Call (888) 764-3080

Close view of the waste fitting in a wash basin

Free to homeowners in The Published Dimensions — the contractor pays us for the introduction, you never do.

Quick answer

The ADA standards give exact heights, diameters and clearances for bathtub grab bars. They apply to public accommodations rather than to houses, but they are the only dimensioned published reference available, which is why they are worth reading before fitting one.

Source: US Access Board, ADA Standards, Chapter 6: Bathing Rooms.

There is a precise, public dimensional standard for this. It governs facilities covered by the ADA rather than private homes, which makes it a reference rather than a requirement — and a good one.

What this site is

TubSet is a referral service, not a contractor. We connect homeowners with independent contractors. Contractors are required to hold whatever credential their state or municipality demands. Every state page sets out who licenses plumbers there and where to check, so you can confirm before work begins. We carry out no work, we sell no fixtures, we do not set prices, and we never charge homeowners anything — the contractors in our network pay us when we route them a call.

What the standard says for a bathtub

ElementDimension
Grab bar height, to top of gripping surface33–36 in
Lower back-wall bar, above the tub rim8–10 in
Circular bar diameter1¼–2 in
Clearance from the wall (absolute)1½ in
Control end wall bar24 in minimum
Back wall bars (two, parallel)24 in minimum each
Head end wall bar12 in minimum

A removable in-tub seat or a permanent seat at the head end is also required; removable seats are 15 to 16 inches deep and 17 to 19 inches high.

The two back-wall grab bar heights the ADA standards publishAn elevation of the back wall of a bathtub. Two parallel grab bars run along it, each drawn at the published minimum length of 24 inches. A dimension from the floor gives the height to the top of the gripping surface as 33 to 36 inches. A second dimension from the tub rim gives the lower bar as 8 to 10 inches above it. The rim height itself is drawn only so the second dimension has something to measure from and carries no figure, because the standard does not set one.bathtubrim24 in minimum eachtwo bars, parallel8–10 inabove the tub rim33–36 into the top of the grippingsurface
Every figure here is a row of the published table. These are the ADA standards, and they apply to facilities covered by the ADA rather than to private dwellings — nothing about them makes a home grab bar "ADA required". They are a set of dimensions worked out by people who had to get it right, and a better reference than guessing.

Source: US Access Board, ADA Standards, Chapter 6: Bathing Rooms.

And the scope, which matters

These are the ADA standards. They apply to facilities covered by the ADA, not to private dwellings. Nothing here says a house must meet them, and anybody who tells you a home grab bar is "ADA required" is wrong.

What they are is a set of dimensions worked out carefully by people who had to get it right, available free, and a better reference than guessing.

The one that surprises people

The 1½ inch clearance from the wall is an absolute dimension rather than a minimum. Closer and a hand cannot get round the bar; further and an arm can pass behind it, which is its own hazard.

Why the grab bar wall clearance is an absolute dimensionThree sections through a wall with a grab bar mounted on it. In the first the gap between wall and bar is less than one and a half inches and a hand cannot get round the bar. In the second it is exactly one and a half inches, the published dimension. In the third it is more than one and a half inches and an arm can pass behind the bar.LESS THAN 1½ INwalla hand cannot getround the bar1½ INwallthe absolutedimensionMORE THAN 1½ INwallan arm can passbehind it1¼–2 in bar diameterTHE CLEARANCE IS ABSOLUTE, NOT A MINIMUM
One and a half inches is an absolute figure rather than a minimum, which is the part that surprises people: closer and a hand cannot get round the bar, further and an arm can pass behind it, which is its own hazard. As above, the ADA standards govern facilities covered by the ADA and not private dwellings.

What actually holds a grab bar up

Not the tile, and not a hollow wall. A bar has to land in framing or in blocking installed for it, and that is why fitting one properly is a job rather than a purchase.

It is also the one moment when it costs least: while the wall is already open for other work.

Where to put it, given the research

At the exit. CDC found 37.3% of bathroom injuries happened bathing, showering or getting out, against 2.2% getting in, so a handhold positioned for the way out is doing most of the available good.

Source: CDC, MMWR: Nonfatal Bathroom Injuries Among Persons Aged ≥15 Years, United States, 2008.

Changing a tub is mostly about what is behind it.Tell us what you want done and we will route you to a contractor in your area, found from your ZIP code, who can look at the wall and the floor before quoting. No charge to you, and we will not ask you why. Anything else needing a plumber is fine to bring up while we have you.

Call (888) 764-3080
Bath standing on its frame while the waste and overflow kit is assembled
Bath filled with water with a mixer tap at one end
Call (888) 764-3080